Indirectly heated unvented storage water heaters with a high output heat exchanger

Buffer Boiler L 300 – L 500 – L 800 – L 1000 with two heat exchanger
29/01/2018
Indirectly heated unvented storage water heaters with two double high output heat exchangers
27/09/2017
14740264540_ΔΟΧΑΔΡΑΝΤΘΕΡΜΟΤ1
  • Enameled steel water tank
  • Highly efficient CFC FREE 50 mm polyurethane insulation
  • Anode protection
  • External Thermoindicator
  • Safety valve
  • Pocket for thermosensor
  • Recirculation connection
  • Access to the inside of the water tank through easily removable flange
  • Plastic external cover
  • Possibility to install heating element
 
Technical Characteristics
Capacity [l] 495
Net weight [kg] 152
Insulation (soft PU) [mm] 50
Heat exchanger surface S1 [m²] 3.4
Heat exchanger capacity S1 [l] 23.3
Exchanged power in continuous mode (max coil output) S1 *60-80 / 70-90°C [kW] 100 / 135
Continuous flow rate of DHW at ∆T 35°C (S1) *60-80 / 70-90°C [l/h] 2448 / 3306
Maximum quantity of drawn off water MIX 45°C (**15-60°C), Power input cut off (S1) [l] 553
Heat losses ∆T 45K [kWh/24h] 2.3
Energy efficiency class C
Maximum operational temperature [°C] 95
Maximum operational temperature of heat exchanger [°C] 110
Rated pressure
  • 0%
  • 8
    Rated pressure of the heat exchanger
  • 0%
  • 6
    Thermo pockets [pieces] 3

    Gallery



    Related Products

    English