Vertical Boiler 2500 L- 3000 L- 4000 L- 5000 L

Stainless steel boiler 1000 L – 2000 L – 2500 L – 3000 L – 4000 L – 5000 L
27/09/2017
Buffer Boiler L 300 – L 500 – L 800 – L 1000
27/09/2017
13061413780_boil_double_vert01

DHW producer with removable U-profile tubular heat exchanger. The DHW heating (secondary circuit), consists in natural convention in the storage tank, lapping against the external part of the tubes which compose the exchanger, which is feeded by the heating fluid (primary circuit). The heating fluid can be hot water, steam or recovered hot fluids (recover circuit), condensation, cooling circuit, etc.

The principal charatteristic of this series’ producer is the use of low thermal power by the thermal generator with the need to store large water quantities and short use time. Properly considering the water demand of DHW and prorating the storage tank capacity and the heat exchanger dimension, is possible to reach high working economies

 
Specifications and Models
Model 2500 3000 4000 5000
Real storage capacity liters 2605 2910 3710 4945
d Diameter without insulation mm 1250 1250 1400 1600
D Diameter with insulation mm 1350 1350 1500 1700
HT Total height mm 2500 2750 2800 2830
L Total lenght (horizontal version) mm 1440 2680 2780 2860
IS Feet distance (horizontal version) mm 1470 1720 1720 1720
FL Flange diameter mm 350 Χ 430
SS1 Heating area tubular heat exchanger 5 6 8 10
FL Flange diameter mm 400Χ480
SS1 Heating area tubular heat exchanger 5 6 8 10
K Leaning height mm 2823 3045 3176 3305
Tare weight 6 bar version kg 345 380 555 660
Tare weight 8 bar version Kg 430 475 770 790
Tare weight 10 bar version Kg 515 565 895 915
Connections
E Cold water inlet G2”½ G2”½ G3” G3”
U Hot water outlet G2”½ G2”½ G3” G3”
RC Recirculation G2”½ G2”½ G3” G3”
RE Electrical resistance connection G2” G2” G2” G2”
S Discharge G1”¼ G1”¼ G1”¼ G1”¼
A Magnesium anode connection G1”½ G1”½ G1”½ G1”½
So Probe connection G½” G½” G½” G½”
T Thermometer/Thermostat connection G½” G½” G½” G½”
P Primary circuit connection G2” G2” G2” G2”
AE Electrical anode connection G½” G½” G½” G½”
Technical data
PE Max. working temperature(storage) bar 6 6 6 6
PC Testing pressure (storage) bar 9 9 9 9
Heat exchanger max. working temperature bar 9 9 9 9
Heat exchanger testing pressure bar 14 14 14 14
TE Max. continous working temperature °C 65 65 65 65
TE Peak temperature °C 81 81 81 81
TE Max. working temperature °C 100 100 100 100
TE Heating coil max. working temp. °C 100 100 100 100