Controllers

Solar System Forced Circulation
30/08/2017
Solar Kit - Σταθμοί Ανακυκλοφορίας 2
Solar Kit
26/09/2017
14399779160_400

EU 400

Solar collector controller

EU-400 regulator is intended for controlling solar collector installation. It controls the main pump (collector pump) using temperature data measured on the collector and accumulation tank.

Optionally, it is possible to connect additional devices such as mixing pump or electric heater as well as to send a signal to initiate fire-up of the CH boiler. Controlling the mixing pump and sending CH boiler fire-up signal may be done directly from the controller whereas controlling the heater requires an additional signal relay.

Functions performed by the controller:

  • Pump operation control
  • Pump speed control
  • One configurable voltage output
  • Operating modes (vacation, defrosting)
  • Supervision and handling of the solar system operation
  • Protection against overheating and freezing of the collector
  • Anti-stop function
  • Anti-freeze function

Equipment of controller:

  • LED display
  • Collector temperature sensor
  • Accumulation tank temperature sensor
  • Casing made of high quality material resistant to high and low temperatures
400sxed
eu400_1
Specifications
Specifications Unit
Supply voltage V 230V/50Hz +/-10%
Maximum power consumption W 4
Ambient temperature °C 5÷50
Maximum output load A 1
Accuracy of measurement °C +/- 1
Range of temperature settings °C 5÷90
Thermal resistance of the sensors °C -25÷90
Fuse-link A 1,6
14151841780_401n

EU 401 N

Solar collector controller

EU-401N type thermoregulator is intended for operation of solar collector systems. This device controls the main (collector) pump on the basis of temperature measurement on the collector and in the accumulation tank.

It may be connected to additional devices such as a mixing pump or an electric heater. It also enables to send a signal to the CH boiler to fire it up. Control of the circulation pump and sending the firing-up signal to the CH boiler is possible directly from the controller whereas in the case of the heater control an additional signal relay is necessary.

Functions performed by the controller:

  • Control of the operation of pumps
  • Supervision and handling the solar system operation
  • Protection against overheating and freezing of the collector

Equipment of controller:

  • Large and clear LCD display
  • Collector temperature sensor
  • Heat accumulator temperature sensor
  • Casing made of high-quality materials resistant to high and low temperatures

Manual EU 401 GR EN

14152553510_st-402-03a
eu401n_1
Specifications
Specifications Unit
Supply voltage V 230V/50Hz +/- 10%
Maximum power consumption W 4
Accuracy of measurement °C 1
Range of temperature settings °C 8÷90
Thermal resistance of the tank sensor °C -25 : 100
Thermal resistance of the collector sensor °C -24÷90/-30÷180 (krótkotrwała 200°C)
Type of collector sensor PT1000
Output load of the collector pump A 1
Output load of the additional device A 1

14151841780_401n

EU 402 N

Solar collector controller

EU-402N


Functions performed by the controller:

  • Control of the pumps (or a pump and a valve)
  • Supervision and handling the solar system operation for 15 configurations of the system
  • Protection against overheating and freezing of the collector
  • The possibility of connecting EU-500 ETHERNET module
  • The possibility of connecting EU-65 GSM module
  • The possibility of connecting an additional device: (circulation pump or heater)
  • Sending a signal to the Central Heating boiler to fire it up

Equipment of controller:

  • Large and clear LCD display
  • Collector temperature sensor
  • Heat accumulator temperature sensor
  • Casing made of high-quality materials resistant to high and low temperatures

Manual EU 402N GR EN

14152553513_st-402-10c
eu401n_1
Specifications
Specifications Unit
Supply voltage V 230V/50Hz +/- 10%
Maximum power consumption W 4
Ambient temperature °C 5÷50
Maximum output load A 1
Accuracy of measurement °C 1
Thermal resistance of the sensors °C -30÷180
Fuse-link A 3,15
Range of temperature settings °C 8÷90
14151841782_460

EU 460

Solar collector controller

EU-460
* color, touch-screen LCD display


Functions performed by the controller:

  • Control of the operation of pumps (or a pump and a valve)
  • Supervision and handling of the solar system operation for 11 configurations
  • Protection against overheating and freezing of the collector
  • The possibility of connecting EU-500 ETHERNET module
  • The possibility of connecting EU-65 GSM module
  • The possibility of connecting an additional device: (circulation pump or heater)
  • Sending a signal to the Central Heating boiler to fire it up

Equipment of controller:

  • Color, clear, touch-screen
  • Collector temperature sensor
  • Heat accumulator temperature sensor
  • Casing made of high-quality materials resistant to high and low temperatures

Manual EU 460

460
Specifications
Specifications Unit
Supply voltage V 230V/50Hz +/- 10%
Maximum power consumption W 4
Ambient temperature °C 5÷50
Maximum output load A 1
Accuracy of measurement °C 1
Thermal resistance of the sensors °C -30÷180
Fuse-link A 3,15
Range of temperature settings °C 8÷90

14151860780_STDC

STDC – MTDC – LTDC

From small to complex: The TDC controllers make every solar system intuitively operable.

  • Clearly written illuminated full text display.
  • Convenient menu with text and graphic mode without confusing abbreviations.
  • Internationally understandable with up to 18 languages included.
  • Self-explanatory operation: The assigned functions are shown in the display right above the respective input key.
  • Easy and quick installation with the integrated setup wizard.
  • Several pre-defined and extendible hydraulic variants for reliable configuration of individual systems.
  • Different options of assembly such as wall assembly, integration to a pump group or mounting to a switch panel.

Depending on the type of device, different options for enhancement are provided:

  • Ethernet or CAN Bus interface for remote control and data logging
  • 0…10V and PWM output for speed-control of high-efficiency pumps
  • Freely assignable relays for flexible function extension
  • UL/CSA-approved 115V version for North America available
  • Manuals, labels, software and hardware can be adjusted for OEM customers.

Specifications
STDC MTDC LTDC
Temperature sensor inputs Pt1000 3 3 5-Ιουν
Relay outputs 230V 1 2 3
of which for speed control of standard pumps 0-1 0-1 0-2
Outputs 0..10V or PWM signal 0-1 0-1 1-2
Number of applications 9 25+ 36+
Simple heat metering Yes Yes Yes
Flow based heat metering (VFS sensor) No No 0-2
Pressure monitoring (RPS sensor) No No 0-2
Time and temperature-controlled thermostat function Yes Yes Yes
Battery-backed Real Time Clock Yes Yes Yes
Setup wizard Yes Yes Yes
Data storage with statistics and graphic analysis Yes Yes Yes
Error memory and analysis with date and time Yes Yes Yes
Ethernet connection (optional) No No Yes      (via Data Logger)